34.5. Frequently Asked Questions
Question Answer
1. Can ESIM264 operate as standalone device without SIM
card inserted?
Yes, ESIM264 device can fully operate without any SIM card inserted. In this case
you will not be able to congure and control the device by SMS and calls nor to
receive any SMS reports and calls.
2. I am unable to arm the alarm system when one of the
zones (some zones) is violated, although I was able
to perform disarming. Is there a way to arm the alarm
system while the zone is violated?
Due to security reasons it is recommended to restore the violated zone (-s)
before arming the alarm system. However, you can enable a Force attribute
or use the Bypass feature in order to arm the alarm system despite the vio-
lated zone (-s) being present. Please, refer to 14.5. Zone Type Denitions
and 14.7. Bypassing and Activating Zones.
3. I have activated ATZ mode in ELDES Conguration Tool
software, but I am unable to set the connection Type 5.
Whenever I select Type 5 and press the “Write Settings”
button it switches back to Type 4. What’s wrong?
It appears that your ELDES Conguration Tool software is outdated. Please,
download the latest ELDES Conguration Tool software version by visiting
www.eldes.lt/en/download.
4. When ESIM264 fully powers down my conguration
becomes lost and I have to re-congure the device
again. What’s wrong?
This might have happened due to the jumper left on DEF pins or it is a hard-
ware failure. Please, remove the jumper if it is present on DEF pins or contact
your supplier for warranty service.
5. I have a smoke detector connected to ESIM264 system.
How do I reset the smoke detector when the “Fire” zone
is violated?
If the smoke detector is connected to one of the Esim264 PGM outputs
you can reset it by turning the PGM output OFF and then back ON. This
can be performed by SMS, EKB2 keypad, EKB3 keypad and ELDES Congu-
ration Tool software. Please, refer to 18.4. Turning PGM Outputs ON and
OFF.
6. What happens if I switch backup battery pole terminals
places?
Switching backup battery pole terminals places is forbidden. Otherwise this
will lead to blown fuse and ESIM264 alarm system will have to be repaired.
7. How do I disable SMS reports and calls in case of tamper
violation when alarm system is disarmed?
The SMS reports on tamper violation can be disabled by EKB2, EKB3 keypads
or ELDES Conguration Tool software. For mor details, please refer to 16.
TAMPERS or to the software’s HELP section. However, due to security
reasons it is not recommended to disable this feature.
8. Is any additional conguration necessary when con-
necting EPGM1 module after wiring is done accroding to
EPGM1 user manual?
No additional conguration is required in order to make EPGM1 module
operational.
9. Does the number of EPGM1 zones duplicate when ATZ
mode is activated in the system?
No, the number of EPGM1 zones does not duplicate in ATZ mode as
EPGM1 module does not support ATZ mode. Only ESIM264 zones
duplicate in ATZ mode.
10. I connect the wired siren to ESIM264 and I hear a silent
sound alarm even when the alarm system is disarmed.
In case of alarm system alarm the siren provides a loud
sound alarm as it should. Why?
Please, connect the resistor of 3,3 k nominal to the BELL- / BELL+ contacts
This should solve the problem.
11. I am using Windows operating system. The windows
of ELDES Conguration Tool are not fully displayed and
some parts are like cut-o. What’s wrong?
Please, update ELDES Conguration Tool software by visiting www.eldes.lt/
en/download and downloading the latest version.
12. The buzzer remains active when I disarm the alarm
system using the keypad. Why?
The buzzer is intended for iButton indication only and it is not related to
disarming process by keypad.
13. One of wireless devices connected to ESIM264 system
sends a tamper alarm from time to time, although no
tamper was violated. Why?
This happens due to wireless connection loss. There might be several reasons:
1. ELDES wireless device is installed too close or too far from ESIM264
system.
2. Interference of other electronic equipment.
3. Physical interference (building walls, oors etc.)
4. Metal material interference.
14. I have connected a wired magnetic door sensor, but
I receive tamper alarm instead of zone alarm. What’s
wrong?
This happens due to incorrect resistor connection. Please, refer to corre-
sponding connection circuit according to the selected zone connection type
(Type 1 – 5). See 2.3.2 Zone Connection Types for more details.
15. I disconnected the backup battery, but did not receive
any SMS report on this event. How do I enable SMS
report on backup battery disconnection?
By default, this notication is enabled. The system checks the backup
battery resistance once a day and sends an SMS report to User 1 on backup
battery replacement if more than 2 resistance is detected. For more details,
please refer to 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS
MONITORING AND MEMORY.