107
107EN
MANUAL ELDES ESIM264 V3.1
By default, if the initial attempt to transmit data to the monitoring station’s phone number via CSD method is unsuccessful, the system will
make up to 4 additional attempts. If all attempts are unsuccessful, the system will switch to next backup connection that follows in the
sequence and will attempt to transmit data until it is successfully delivered to the monitoring station.
Set attempts
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → MS SETTINGS → OK → CSD SETTINGS → OK →
TEL. NUMBER 1... 5 → OK → OK
Value: aaaa – 4-digit administrator password; at – number of attempts, range – [1... 10].
EKB3
Enter parameter 84 & number of attempts:
84 at #
Value: at – number of attempts, range – [01... 10].
Example: 8403#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.