31.1.1.3. Visual and Audio Indications
EKB2 can be used even in dark premises as the LCD screen and keys are illuminated continuously. The illumination level lowers down if 3 min-
utes after the last key-touch expires while the system is disarmed. In case of alarm, the keypad illumination level is boosted and stays in this
state until the system is disarmed.
The built-in buzzer uses two types of sound signals – three short beeps and one long beep. Three short beeps stand for successfully carried
out conguration, one long beep – for invalid conguration. In addition, the buzzer emits short beeps in case of alarm and exit/entry delay
countdown.
31.1.1.4. EKB2 Zone and Tamper
Keypad EKB2 has one wired zone Z1 and one tamper button. By default, the keypad zone Z1 is disabled. The keypad zone can be enabled by
SMS, EKB2 keypad, EKB3 keypad and ELDES Conguration Tool software (see 14.9. Disabling and Enabling Zones). When Z1 is enabled,
it operates like any other system zone, therefore a sensor can be connected to it. In addition, Z1 and COM terminals must be connected with
resistor of 5,6k nominal.
The tamper button is intended for monitoring the enclosure status of EKB2, therefore the system causes alarm if the enclosure is illegally
opened. Keypad zone Z1 must be enabled and resistor connected even if the tamper button alone is required.
31.1.1.5. Icons and Messages
Icon / Message Description
Chime - Delay zone violated when system
is disarmed.
Exit delay countdown initiated.
System is armed and menu is locked.
System is disarmed and menu is unlocked
+ CONFIGURATION
MODE
Conguration mode activated.
BURGLARY ALARM
Delay, Instant or Follow zone violated
when system is armed.
Icon / Message Description
24 ALARM
24H zone violated.
FIRE ALARM
Fire zone violated.
TAMPER ALARM
Tamper violated
READY
System is ready to be armed.
NOT READY
System is not ready to be armed – one or
more zones / tampers violated.
ARMED
System is armed (optional feature).
STAY
Stay mode activated
BYP
System armed in Stay mode
TBL
One or more system faults are present