116
116 EN
MANUAL ELDES ESIM264 V3.1
31.1.2. EKB3 - LED Keypad
EKB3 is a LED keypad intended for using with ESIM264 alarm system.
Main EKB3 features:
• Alarm system arming and disarming (see 12.4. EKB3 Keypad and User Password).
• Arming and disarming in Stay mode (see 15. STAY MODE).
• System parameter conguration (see 5. CONFIGURATION METHODS).
• PGM output control (see 18.4. Turning PGM Outputs ON and OFF).
• Visual indication by LED indicators (see 31.1.2.3. Visual and Audio Indications).
• Audio indication by built-in buzzer (see 31.1.2.3. Visual and Audio Indications).
• Keypad partition switch (see 23.3. Keypad Partition and Keypad Partition Switch).
The system conguration by EKB3 keypad is performed by activating the Conguration mode (see 5. CONFIGURATION METHODS) and en-
tering the required parameters & values. ESIM264 system allows to connect up to 4 EKB3 keypads.
31.1.2.1. Technical Specications
31.1.2.1.1 Electrical & Mechanical Characteristics
Power Supply 12-14V 150mA max
Maximum Keypad Connection Cable Length 100 m.
Dimensions 140x100x18mm
Humidity
0-90% RH @ 0... +40 °C (non-condensing)
Range of Operating Temperatures -30...+55ºC
31.1.2.1.2 LED Functionality
ARMED Steady ON - alarm system is armed / exit delay in progress; ashing - Conguration mode activated
READY Steady ON - system is ready – no violated zones and tampers
SYSTEM Steady ON - system faults; ashing - violated high-numbered zone (Z13-Z44)
BYPS Steady ON - zone bypass mode
1-12 Steady ON - violated zone Z1... Z12
31.1.2.1.3 Keys Functionality
[BYPS] Zone bypass mode
[CODE] System fault list / violated high-numbered zone indication / violated tamper indication
[*] 1st character for Conguration mode activation/deactivation command / clear typed in characters / keypad partition swi-
tch (if enabled)
[#] Conrm (enter) command
[0] ... [9] Command typing
[STAY] Manual system arming in Stay mode
[INST] N/A
31.1.2.1.4 Connector Functionality
AUX+ Positive power supply terminal
AUX- Negative power supply terminal
G RS485 interface for communication (green wire)
Y RS485 interface for communication (yellow wire)
COM Common terminal for Z1
Z1 Security zone terminal
Z2 N/A
3, 2 Keypad address pins
1 N/A