116
116 EN
MANUAL ELDES ESIM264 V3.1
31.1.2. EKB3 - LED Keypad
EKB3 is a LED keypad intended for using with ESIM264 alarm system.
Main EKB3 features:
Alarm system arming and disarming (see 12.4. EKB3 Keypad and User Password).
Arming and disarming in Stay mode (see 15. STAY MODE).
System parameter conguration (see 5. CONFIGURATION METHODS).
PGM output control (see 18.4. Turning PGM Outputs ON and OFF).
Visual indication by LED indicators (see 31.1.2.3. Visual and Audio Indications).
Audio indication by built-in buzzer (see 31.1.2.3. Visual and Audio Indications).
Keypad partition switch (see 23.3. Keypad Partition and Keypad Partition Switch).
The system conguration by EKB3 keypad is performed by activating the Conguration mode (see 5. CONFIGURATION METHODS) and en-
tering the required parameters & values. ESIM264 system allows to connect up to 4 EKB3 keypads.
31.1.2.1. Technical Specications
31.1.2.1.1 Electrical & Mechanical Characteristics
Power Supply 12-14V 150mA max
Maximum Keypad Connection Cable Length 100 m.
Dimensions 140x100x18mm
Humidity
0-90% RH @ 0... +40 °C (non-condensing)
Range of Operating Temperatures -30...+55ºC
31.1.2.1.2 LED Functionality
ARMED Steady ON - alarm system is armed / exit delay in progress; ashing - Conguration mode activated
READY Steady ON - system is ready – no violated zones and tampers
SYSTEM Steady ON - system faults; ashing - violated high-numbered zone (Z13-Z44)
BYPS Steady ON - zone bypass mode
1-12 Steady ON - violated zone Z1... Z12
31.1.2.1.3 Keys Functionality
[BYPS] Zone bypass mode
[CODE] System fault list / violated high-numbered zone indication / violated tamper indication
[*] 1st character for Conguration mode activation/deactivation command / clear typed in characters / keypad partition swi-
tch (if enabled)
[#] Conrm (enter) command
[0] ... [9] Command typing
[STAY] Manual system arming in Stay mode
[INST] N/A
31.1.2.1.4 Connector Functionality
AUX+ Positive power supply terminal
AUX- Negative power supply terminal
G RS485 interface for communication (green wire)
Y RS485 interface for communication (yellow wire)
COM Common terminal for Z1
Z1 Security zone terminal
Z2 N/A
3, 2 Keypad address pins
1 N/A