76 EN
MANUAL ELDES ESIM264 V3.1
Disable mains
power supply restore
notication
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK SMS MESSAGES OK MAIN PWR REST EV
OK DISABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 05 0 #
Example: 25050#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Enable mains power
supply restore
notication
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK SMS MESSAGES OK MAIN PWR REST EV
OK ENABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 05 1 #
Example: 25051#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
By default, mains power supply loss and restore delay are 30 and 120 seconds respectively. To set a dierent mains power supply loss and
restore delay duration, please refer to the following conguration methods.
Set mains power
supply loss delay
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETT INGS OK MAIN POWER
STATUS OK LOSS DELAY OK lllll OK
Value: aaaa – 4-digit administrator password; lllll – mains power loss delay duration, range
- [0... 65535] seconds.
EKB3
Enter parameter 70 & loss delay duration:
70 lllll #
Value: lllll – mains power loss delay duration, range - [0... 65535] seconds.
Example: 7043#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Set mains power
supply restore delay
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETT INGS OK MAIN POWER
STATUS OK RESTORE DELAY OK rrrrr OK
Value: aaaa – 4-digit administrator password; rrrrr – mains power restore delay duration,
range - [0... 65535] seconds.
EKB3
Enter parameter 71 & restore delay duration:
71 rrrrr #
Value: rrrrr – mains power restore delay duration, range - [0... 65535] seconds.
Example: 71150#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
The conguration settings and event log records are stored in a built-in EEPROM memory, therefore even if the system is fully shut down,